Acceptable fluid |
Flow velocity (m/s) |
Output |
Pipe size range (mm) |
Linearity |
Sensor body |
Electrodes |
Liner |
Fluid temperature (°C) |
Max operating pressure (bar) |
ATEX approval |
| Magnetic Flow Sensor Magflux F5 |
Conductive liquids |
0.25 - 10 |
Frequency, 4 to 20 mA |
2 - 12 |
± 0.15% |
Zirconium oxide |
Platinum |
Zirconium oxide |
150 max |
25 (higher on request) |
Yes |
| Magflow Meter Signet 2551 |
Conductive liquids |
0.05 - 10 |
Frequency/digital, 4 to 20 mA |
15 - 300 |
± 1% |
PP or PVDF |
Stainless steel, titanium or Hastelloy C |
n/a |
0 to 85 |
10.3 |
No |
| Magflow Meter Signet 2552 |
Conductive liquids |
0.05 - 10 |
Frequency/digital, 4 to 20 mA |
50 - 2550 |
± 1% |
Stainless steel |
Stainless steel |
n/a |
-15 to +85 |
20.7 |
No |
| Magnetic Flow Meter SITRANS F M Magflo MAG 1100 |
Conductive liquids |
0.05 - 10 |
Frequency 4 to 20 mA, PROFIBUS DP & PA, DeviceNet, HART, CANopen, MODBUS |
10 – 100 (PFA) 2 – 100 (ceramic) |
± 0.5% (with MAG 5000) ± 0.25% (with MAG 6000) |
Stainless steel |
Hastelloy C (PFA) Platinum (ceramic) |
PFA or ceramic |
-30 to +130 (PFA) -20 to +150 (std ceramic) -20 to +200 (high temp ceramic) |
20 (PFA) 40 (ceramic, 2 – 65 mm) |
Yes (Ex version) |
| Magnetic Flow Meter SITRANS F M Magflo MAG 5100 W |
Conductive liquids |
0.05 - 10 |
Frequency 4 to 20 mA, PROFIBUS DP & PA, DeviceNet, HART, CANopen, MODBUS RTU/RS485 |
25 - 1200 |
± 0.5% (with MAG 5000) ± 0.25% (with MAG 6000) |
Carbon steel |
Hastelloy C |
Hard Rubber or EPDM |
-5 to +70 |
40 |
No |
| Magnetic Flow Sensor Magflux S |
Conductive liquids |
0.25 - 10 |
Frequency, 4 to 20 mA |
15 - 100 |
± 0.15% |
Zirconium oxide |
Stainless steel & special materials |
PVDF, PVC |
-15 to +60 |
18 (at 10°C) |
Yes |
| Magnetic Flow Meter SITRANS F M Magflo MAG 3100 |
Conductive liquids |
0.05 - 10 |
Frequency 4 to 20 mA, HART PROFIBUS DP & PA, MODBUS RTU/RS485 |
15 - 2000 |
± 0.5% (with MAG 5000) ± 0.25% (with MAG 6000) |
Carbon steel, Stainless steel |
AISI 316 Ti, Hastelloy C, Platinum, Titanium, Tantalum |
Neoprene, EPDM, PTFE, Ebonite, Linatex, Novolak |
-40 to + 70 ..... -20 to +180, depending on liner |
100 (Neoprene, Ebonite) |
Yes (3100 Ex version) |
| Magnetic Flow Meter SITRANS F M Magflo MAG 8000 |
Conductive liquids |
0.05 - 10 |
Serial RS 232/485 MODBUS, pulse, datalogger option |
25 - 1200 |
± 0.4% of rate ± 2 mm/s (± 0.2% of rate ± 2 mm/s extended accuracy) |
Carbon steel |
Hastelloy C276 |
EPDM |
-5 to +70 |
20 |
No |
| In Line Magnetic Flow Sensors SDI852 |
Conductive liquids |
0 - 80 l/min |
PNP NO / NC, programmable or 4...20 mA, linear |
10 or 15 |
< 2% |
|
Stainless steel |
PVDF |
5 - 60 |
10 |
No |
The data above is intended as a guide for selection. Please check datasheets before specifying