Acceptable fluid |
Flow tube design | Nominal size (mm) | Flow range (kg/min) | Accuracy * | Transmitter/indicator | Operating temperature (°C) | Max operating pressure (bar) | ATEX approval |
| Coriolis Meter OVAL ULTRAmass MKII |
Liquid, gas |
2 ‘U’ tubes | Liquid: 3 - 150 (9 model) Gas: 3 - 80 (7 models) | Liquid: 0 - 6200 Gas: 0 - 4000 | Liquid: ± 0.1% Gas: ± 0.5% | Integral or remote mount | -200 - +200 | 94 430 (high pressure version for gas) | Yes |
| Coriolis Meter OVAL STmass MKII |
Liquid |
Single straight tube | 15 - 80 (6 models) | 0 - 1800 | ± 0.2% | Integral or remote mount | -25 - +130 | 24.5 | Yes |
| Coriolis Meter OVAL VRmass |
Liquid, slurries |
2 rainbow-style tubes | 10 - 50 (5 models) | 0 -1600 | ± 0.4% | Integral or remote mount | -40 - +125 | 79 | Yes |
| Coriolis Meter OVAL CoriMate |
Liquid |
Single coiled tube | 0.7 - 3.0 (3 models) | 0.0025 - 2.7 | ± 0.4% | Integral, one piece construction | -10 – +60 | 20 | No |
| Coriolis Meter OVAL MassFlex |
Liquid, gas |
Single ‘U’ tube | ¼ inch | 0.002 - 0.225 | ± 0.2% ± 0.015%FS | Remote mount | -200 - +200 | 150 (liquids), 10 (gas) | No |