Pulse output without display and a synthetic resin body makes the Eggs DELTA Pulse flow meter from Oval an inexpensive, compact option for flow measurement, which is ideal for consumption monitoring and control of water, gas or air.
Specification Detail of the Eggs DELTA Pulse Vortex Flowmeter:
Pipe Size
DN4 – DN25 Material Body PPS plastic resin Flow Range Liquid: 0.4 – 133 l/m, Gas: 7.2 – 850 l/m |
Accuracy
Liquids: ±2% of full scale Gas: ±3% of full scale Operating Temp Range –10 to +80°C Pressure Range Up to 0.98MPa |
Outputs
Analog, pulse (flowrate, alarm) Fluid Type Liquid (cooling water, pure water), gas (air, nitrogen) Configuration Non-explosionproof, IP53 equivalent |
Power
DC-powered or battery-powered Approvals ATEX, TIIS, Exia II B T4, Exia II B T4 Ga/Gb Connection R male screw (plastic resin), Rc female screw (metal), NPT male screw (plastic resin) |
Looking for help with flow rate, pipe diameter or flow velocity? |
OUR PARTNERS |
OUR CUSTOMERS |