Numerous principles of operation and design variations together with the consideration of installation parameters, location and the economies of operation can make it a daunting task when choosing the right flow meter for a particular application.
If you don’t know the difference between vortex flow, Magflow or mass flow technologies then you’re probably not going to make the right choice when it comes to selecting a flow meter.
iCenta is a UK flow meter specialist supplying some of the leading names in liquid, gas & vapour flow measurement with clients both large and small. To help you take the guesswork out of choosing a flow meter, please refer to the table below or just get in touch with our technical sales team.
If you don’t know the difference between vortex flow, Magflow or mass flow technologies then you’re probably not going to make the right choice when it comes to selecting a flow meter.
iCenta is a UK flow meter specialist supplying some of the leading names in liquid, gas & vapour flow measurement with clients both large and small. To help you take the guesswork out of choosing a flow meter, please refer to the table below or just get in touch with our technical sales team.
Liquids | Gear | Turbine | Magnetic | Coriolis | Thermal | Vortex | Paddlewheel | Ultrasonic | V/A | Rotameter |
Clean | Yes | Yes | Yes | Yes | No | Yes | Yes | Yes | Yes |
Dirty | No | No | Yes | Yes | No | Yes | Special Design | Yes | Yes |
Conductive | Yes | Yes | Yes | Yes | No | Yes | Yes | Yes | Yes |
Viscous | Yes, >10 (cst) | Yes (Special Calibration) | Yes | Yes | No | No | Yes | Yes | Yes (Special Calibration) |
Slurries | No | Limited | Yes | Yes | No | Yes | No | Yes (Doppler) | No |
Corrosive | Yes | Yes | Yes | Yes | No | Yes | Yes | Yes | Yes |
Reverse Flow | Yes | Yes | Yes | Yes | No | No | Yes | Yes | No |
Pulsating Flow | Yes | Yes | Yes | Yes | No | Yes | Yes | Yes | Yes |
Semi Filled Pipes | No | No | No | No | No | No | No | Yes | No |
Open Channel | No | No | No | No | No | No | No | Yes | No |
Gases | Gear | Turbine | Magnetic | Coriolis | Thermal | Vortex | Paddlewheel | Ultrasonic | V/A | Rotameter |
Steam | No | Yes | No | Yes | No | Yes | No | Yes | Yes |
Clean | Yes | Yes | No | Yes | Yes | Yes | No | Yes | Yes |
Wet | Yes | Yes | No | Yes | No | Yes | No | Yes | Yes |
Contaminated | No | No | No | Yes | No | Yes | No | Yes | No |
Corrosive | No | Yes | No | Yes | No | Yes | No | Yes | Yes |
Tech Data | Gear | Turbine | Magnetic | Coriolis | Thermal | Vortex | Paddlewheel | Ultrasonic | V/A | Rotameter |
Accuracy ± | 0.1-0.5% of reading | 0.25-1% of reading | 0.5-1% of reading | 0.05-0.15% of reading | 1.5% full scale | 1% of reading | 1% (linearity) | typically 1-5% of reading | 2-4% full scale |
Repeatability ± | 0.1% of reading | 0.1% of reading | 0.1% of reading | 0.05-0.10% of reading | 0.5% full scale | 0.2% of reading | 0.25% full scale | ||
Max Pressure Bar | 270 and up | 350 and up | 350 and up | 85 and up | 40 and up | 50 and up | 100 and up | unlimited | 15 and up |
Max Temp | 125 and up | 300 and up | 150 and up | 200 and up | 100 and up | 400 | 100 and up | 100 and up | 300 and up |
Pressure Drop | Medium | Medium | Virtually None | Low | Low | Low | Virtually None | None | Medium |
Turndown Ratio | 25:1 | 10:1 | 100:1 | 50:1 | <10:1 | 10:1 | |||
Average Cost | Medium | Medium | Medium | High | Medium | Medium | Low | Medium | Low |