Parameter Comparison Table
Fluids | Application | Nominal size (mm) | Flow rate range (m/s) | Flow rate accuracy | Level range (m) | Level accuracy | Operating temperature (°C) | Max operating pressure (Bar) | ATEX approval | |
Ultrasonic Flow Meters 190P and 190PLT | Liquid | Closed pipe | 15 – 1200 or 1200 – 6500 (190P)15 – 300 (190PLT) | 0.01 – 25 (higher by request) | ±1-2% or ±0.02 m/sec whichever is greater | N/A | N/A | -30 to 105 | No | |
Ultrasonic Flow Meter 190F | Liquid | Closed pipe | 25 – 500; 500 – 1200; 1200 – 6500 | 0.01 – 25 (higher by request) | ±1-2% or ±0.02 m/sec whichever is greater | N/A | N/A | -30 to 105 | No | |
Ultrasonic Flow Meter 190FD | Liquid | Closed pipe | 20 – 1200 | 0.05 – 10 | ±1-3% or ± 0.03 m/sec whichever is greater | N/A | N/A | 0 – 50 | No |
The data above is intended as a guide for selection. Please contact our team of Ultrasonic Flow Meter specialists to find out more, or visit ,our Ultrasonic Flow Meter section on the iCenta website.