Parameter Comparison Table
Fluids | Flow range (l/min) | Nominal size (mm) | Accuracy | Operating Temp (°C) | Max operating pressure (bar) | ATEX approval | |
Vortex Meter OVAL Eggs DELTA | Liquid, gas | Liquid: 0.4 – 133 Gas: 7.2 – 850 |
4, 8, 15, 25 | ± 3% | -10 to +80 | 9.8 | No |
Vortex Meter OVAL Eggs DELTA Metal | Liquid | 2 – 45 | 8, 15 | ± 3% | -10 to +150 | 9.8 | No |
OVAL Eggs DELTA Pulse | Liquid, gas | Liquid: 0.4 – 133 Gas: 7.2 – 850 |
4, 8, 15, 25 | ± 3% | -10 to +80 | 9.8 | Yes |
OVAL Eggs DELTA Pulse Metal | Liquid | 2 – 45 | 8, 15 | ± 3% | -10 to +150 | 9.8 | No |