Fluids | Flow velocity (m/s) | Output | Pipe size range (mm) | Linearity | Sensor body | Electrodes | Liner | Fluid temp (°C) | Max operating pressure (bar) | ATEX approval | |
Sitrans F M MAG 5100W | Conductive Liquids | 0.05-10 | Frequency 4 to 20 mA, PROFIBUS DP & PA, DeviceNet, HART, CANopen, MODBUS RTU/RS485 | 25 – 1200 | ± 0.5% (with MAG 5000) ± 0.25% (with MAG 6000) | Carbon steel | Hastelloy C | Hard Rubber or EPDM | -5 to +70 | 40 | No |
SITRANS MAG 3100 P Flow Sensor | Conductive Liquids | 0.05-10 | Frequency 4 to 20 mA, HART PROFIBUS DP & PA, MODBUS RTU/RS485 | 15-2000 | ± 0.5% (with MAG 5000) ± 0.25% (with MAG 6000) | Carbon steel, Stainless steel | AISI 316 Ti, Hastelloy C, Platinum, Titanium, Tantalum | Neoprene, EPDM, PTFE, Ebonite, Linatex, Novolak | -40 to + 70 ….. -20 to +180, depending on liner | 100 (Neoprene, Ebonite) | Yes (3100 Ex version) |
Mag-flux A Magnetic Flow Sensor | Conductive Liquids | 0.25 – 10 | Frequency, 4 to 20 mA, HART | 15 – 600 | ± 0.15% | Welded steel | Stainless steel & special materials | Hard rubber/soft rubber or PTFE | #Error! | 250 | No |
Mag-flux S Magnetic Flow Sensor | Conductive Liquids | 0.25 – 10 | Frequency, 4 to 20 mA | 15 – 100 | ± 0.15% | Zirconium oxide | Stainless steel & special materials | PVDF, PVC | -15 to +60 | 18 (at 10°C) | No |
2552 Magflow Meter | Conductive liquids | 0.05 – 10 | Frequency/ digital, 4 to 20 mA | 50 – 2550 | ± 1% | Stainless steel | Stainless steel | N/A | -15 to +85 | 20.7 | No |
SITRANS F M MAG 1100 Magnetic Flow Meter | Conductive liquids | 0.05 – 10 | Frequency 4 to 20 mA, PROFIBUS DP & PA, DeviceNet, HART, CANopen, MODBUS | 10 – 100 (PFA) 2 – 100 (ceramic) | ± 0.5% (with MAG 5000) ± 0.25% (with MAG 6000) | Stainless steel | Hastelloy C (PFA) Platinum (ceramic) | PFA or Ceramic | -30 to +130 (PFA) -20 to +150 (std ceramic) -20 to +200 (high temp ceramic) | 20 (PFA) 40 (ceramic, 2 – 65 mm) | Yes (Ex Version) |
SITRANS F M MAG 1100 F Magnetic Flow Meter | Conductive liquids | 0.05 – 10 | Frequency 4 to 20 mA, PROFIBUS DP & PA, HART, MODBUS | 10-100 | ± 0.5% (with MAG 5000) ± 0.25% (with MAG 6000) | Stainless steel | Hastelloy C (PFA) Platinum (ceramic) | PFA (not for EX) or ceramic | -30 to +130 (PFA) -20 to +150 (std ceramic) | 20 (PFA) 40 (ceramic, 10 – 65 mm) 25 (ceramic 80, 100 mm) | Yes |
Mag-flux F5 Magnetic Flow Sensor | Conductive Liquids | 0.25 – 10 | Frequency, 4 to 20 mA | 2 – 12 | ± 0.15% | Zirconium oxide | Platinum | Zirconium oxide | 150 max | 25 (higher on request) | No |
Magflow Meter Signet 2551 | Conductive Liquids | 0.05 – 10 | Frequency/ digital, 4 to 20 mA | 15 – 300 | ± 1% | PP or PVDF | Stainless steel, titanium or Hastelloy C | N/A | 0 to 85 | 10.3 | No |
TRANSMAG 2 with SITRANS F M 911E Magnetic Flow Sensor | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
SITRANS F M MAG 8000 Magnetic Flow Meter | Conductive liquids | 0.05 – 10 | Serial RS 232/485 MODBUS, pulse, datalogger option | 25 – 1200 | ± 0.4% of rate ± 2 mm/s (± 0.2% of rate ± 2 mm/s extended accuracy) | Carbon steel | Hastelloy C276 | EPDM | -5 to +70 | 20 | No |
Danfoss Magflo equivalents | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A |