icenta-flow-meters-logo

DS 52 set. Dew point measurement for desiccant or absorption dryers

partner-page-oval_orig

Downloads

  • Plug-in system
  • 2 alarm contacts
  • Option alarm unit: Buzzer

DS 52 set. Dew point measurement for desiccant or absorption dryers

The measuring range of -80…20°Ctd makes the dew point set DS 52 with alarm the ideal dew point monitor with analogue output 4…20 mA. The dew point sensor FA 510 is extremely long-term stable and can be installed and removed quickly and easily under pressure by means of the screwable measuring chamber including quick coupling. The dew point set is supplied ready for plug-in, i.e. everything is completely wired. The alarm values can be freely adjusted

  • Ideal for all types of adsorption dryers with a measuring range of -80…+20°Ctd.
  • Gas-independent measurement, also suitable for other, non-corrosive gases
  • Compact design, ideal for dryer installations
  • Robust design, protection class IP 66
  • Condensation insensitive sensor element
  • Long-term stability and drift-resistant, thus optimized calibration intervals
  • Fast adaptation time, especially from dry to wet conditions
  • BSP, NPT or UNF threads
  • Analog output 4…20 mA (2- or 3-wire technology) and Modbus RTU (RS 485) interface
  • Measured values available in different units, pressure dew point [°Ctd], temperature [°C], rel. humidity [%rh], abs. humidity [g/m³], degree of humidity [g/kg], humidity fraction V/V [ppmV/V], water vapor partial pressure [hPa], atmospheric dew point [°Ctd.atm].
  • On-site sensor diagnostics with handheld device or CS Service Software

Features:

  • System ready for plug-in: Everything completely wired
  • No time-consuming studying of the instruction manual
  • 2 alarm contacts (230 VAC, 3 A) pre- and main alarm freely adjustable
  • 4…20 mA analogue output
  • Option alarm unit: Buzzer and continuous red light

Specs

Manufacturer: CS Instruments

Part Ref: DS 52

Contact Us Today To Enquire About Our Products And Services


Product Specification
Below is the product specification of the Dew point measurement for desiccant or absorption dryers from CS Instruments. If you require further information about the DS 52, please contact our expert customer service advisors on 01722 442 307.


Dimensions
118 x 92 x 93mm

Display
LED red, 7-segment,
height: 13mm, 5-digit,
2 LED for alarm relay

Input
4…20mA

Power supply
230VAC, 50/60Hz;
option: 24VDC or 110VAC 50/60Hz

Keypad
4 keys

Alarm outposts:
2 x relay output,
changeover contact,
250VAC, max. 3A

Operating temperature
-10…+60°C (storage temperature
-20°C…+80°C)

Alarm thresholds
Freely adjustable

Hysteresis
2°Ctd

Analogue output
4…20mA = -80…
20Ctd or -20…50Ctd.