icenta-flow-meters-logo

LMK 858 Hydrostatic Level Transmitter

partner-page-oval_orig

Downloads

fluidwell-f-series-cc-cx_548
  • Good long term stability
  • Sensor technology
  • High level of accuracy

LMK 858 Hydrostatic Level Transmitter

The Hydrostatic Level Sensor | Transmitter LMK 858 has been developed for continuous level measurement in aggressive media. Usage in more viscous media, for example sludge, is possible because of the semi-flush diaphragm. The basic element is a mechanically robust and highly overloaded capacitive ceramic sensor; the transmitters are among others suited for the measurement of low filling heights with good long term stability. In order to facilitate stock-keeping and maintenance the transmitter head is plugged to the cable assembly with a connector and can be changed easily.

Features of the LMK 858 include:

  • Diameter 45 mm
  • Transmitter head and cable assembly plugged
  • Nominal pressure ranges: 0 to 40 cmWC up to 0 to 100 mWC (0 to 40 mbar up to 0 to 10 bar)
  • Output 4 – 20mA or Volts
  • Sensor technology: thick film/ceramic, capacitive
  • Accuracy: <±0.175%
  • Good long term stability
  • Cable protection with PVC pipe possible
  • Customer specific versions available

General Applications:
​ 

  • Level monitoring in open tanks with low filling heights
  • Depth or level measurement in wells and open waters
  • Ground water level measurement
  • Sewage treatment, water supply
  • Chemical and pharmaceutical industries

Specs

Manufacturer: iCenta

Part Ref: LMK 858-41

IWN: LEV-578368

Liquid: Water, Wastewater, Aggressive Liquids

Media Type: Liquids

Contact Us Today To Enquire About Our Products And Services


Product Specification:
The LMK 858 is a plastic Hydrostatic Submersible Level Transmitter with Ceramic Sensor.A hydrostatic submersible level transmitter that has been developed for continuous level measurement in most aggressive media.

Specification Detail of the LMK 858:


Diameter
45mm

Material Body
PVC

Flow Range
NA

Accuracy
≤± 0.175%

Operating Temp Range
0 to 50°C

Pressure Range 

0.06 to 10 bar g

Outputs & Comms
2/3 wire – 4 …20 mA/ 0… 10 V /3w

Insertion / Inline
Insertion

Fluid Type
Liquid

Applicable Liquids
Water, waste water, aggressive liquids

Power
12 …36 VDC

Approvals

Connection Type
NA