  • Pipe diameter range: DN 200 - DN 2000
  • Measurement accuracy
  • Conductivity requirement

Mag-flex Sonden

The Mag-flux Sonden, is designed to be used in conjunction with the Mag-flux m1.

The Mag-flux MIS 1/D and MIS 2/15 electromagnetic flow sensors are designed for accurate velocity and flow measurement of electrically conductive liquids in large-diameter pipelines. Using a pulsed constant magnetic field these sensors deliver reliable performance independent of temperature, pressure, density, or viscosity.

Engineered for demanding industrial environments, the mag-flux flow probes are ideal for water and wastewater treatment, steel production, and energy or utility applications. With no moving parts, the sensors offer exceptionally low maintenance and long-term operational stability.

Designed for flexible installation, the sensors can be mounted in existing pipelines and even replaced under operating conditions. For improved accuracy in challenging flow profiles, up to two sensors can be connected to a single transmitter to calculate an averaged flow value.

Features of the Mag-flux Sonden include:

  • Suitable for DN 200 up to DN 2000 pipelines
  • Measures conductive liquids
  • Accuracy +3% of reading
  • Flow ranges up to 10 m/s
  • Maintenance-free design with no moving parts
  • Ideal for large pipe diameters and cost-effective retrofitting

Typical Applications:

  • Water treatment
  • Wastewater & sewage
  • Industrial process water
  • Utilities

Specs

Manufacturer: Mecon

Part Ref: MAGFLUX SD

IWN: MAGFLUX-002

Liquid: Clean Water, Water, Wastewater

Media Type: Liquids

Contact Us Today To Enquire About Our Products And Services


Product Specification:

Electromagnetic flow sensor, DN200–2000, ±3% accuracy, IP68 rated.

Specification Detail of the Mag-flex Sonden Magnetic Flow Meters from Mecon:


Pipe Size

DN200 – DN2000

Material Body

PVC, Stainless Steel

Flow Range

Max. 5 m/s

Accuracy

±3% of the reading

Pressure Range

Up to 16bar

Operating Temp Range

Max. 60ᵒC

Insertion / Inline

Insertion

Fluid Type

Clean water, water, wastewater

Applicable Liquids

Water, wastewater

Power

Dependant on Transmitter model

Approvals

CE

Connection Type

Remote sensor with fixed cable to transmitter and welded pipe mounting via fitting aid.