Downloads
- Measuring principle: Magnetic inductive (PDC)
- Outputs: 0/4 - 20 mA, pulse, frequency
- Protection rating: IP67 / NEMA 4X
The Mag-flux M1 is a microprocessor-controlled magnetic inductive transmitter designed for precise flow measurement of conductive liquids. Using a pulsed DC constant field (PDC) measuring principle, it delivers reliable and stable flow signals for demanding industrial applications.
Engineered to process measurement data from compatible mag-flux sensors, the M1 provides accurate monitoring of flow velocities up to 10 m/s in liquids with a minimum conductivity of 3 µS/cm. It is ideally suited for water and wastewater treatment, food and beverage production, and pulp and paper processing.
The transmitter features high-speed 16-bit signal processing, galvanically isolated outputs, and flexible configuration options including 0/4–20 mA analog output, pulse and frequency outputs, and optional HART® communication (Version 7.0). An optional local control unit with illuminated two-line LCD display enables straightforward configuration and real-time monitoring.
Features of the Mag-flux M1 include:
- 16-bit microprocessor-controlled signal processing
- Pulsed DC constant field (PDC) measuring principle
- 0/4-20 mA analog output with optional HART (v7.0)
- Galvanically isolated analog and digital outputs
- Pulse, frequency, and configurable status outputs
- Optional LCD display with multilingual menu navigation
Typical Applications:
- Water treatment
- Wastewater & sewage systems
- Food & beverage processing
- General industrial processing
- Utility metering
Specs
Contact Us Today To Enquire About Our Products And Services
Product Specification:
Mag inductive transmitter, 4–20 mA, HART, IP67
Specification Detail of the Mag-flex M1 Magnetic Flow Meters from Mecon:
Pipe Size
DN 15 – DN 50 (remote version only)
DN 65 – DN 100 (compact or remote version, depending on sensor type)
Material Body
Aluminium
Flow Range
Up to 10 m/s
Accuracy
±0,05 % per 10 K
Pressure Range
Defined by connected mag-flux senso
Operating Temp Range
-20ᵒC to +60ᵒC
Fluid Type
Clean water, water, wastewater, slurry
Applicable Liquids
Water, wastewater
Power
230 V AC ±10%, 50/60 Hz
115 V AC ±10%, 50/60 Hz
24 V DC (18–36 V DC) ±15%
Approvals
CE
Connection Type
Electrical Connections:
Analog output: 0/4 – 20 mA (optional HART – v7.0)
Digital outputs: Optocoupler, passive (max. 30 V, 60 mA, 1.8W)
Pulse / Frequency outputs: Up to 1kHZ