- Small design - easy installation
- Multiple analog or digital signals
- 24 VDC input power reduces installation cost and complexity
MicroTrak™ is specifically designed for flow ranges under 4 mln/min with a minimum controllable mass flow rate of 0.08 mln/min.
The Model 101 is a specialized and highly engineered instrument for those who need accurate and reliable micro mass flow control of clean gases including corrosives and toxic media. MicroTrak™ is based on award-winning family of digital instruments. As a result, ease of operation, field configuration, multi-gas capability and application flexibility are standard features.
The MikroTrak comes standard with all kinds of analog in and set-point abilities and RS232. Optionally you can add the pilot module (as shown in above picture) mounted on the unit or up to 3 meter remote. The pilot module adds a clear back-lit LCD display and the ability to change all kind of setting like set-point and the type of gas used. Alternatively you can add the Compod on the unit that will add Modbus, Advanced alarms, totalizer, analog input, pulse output and a lot more. See
separate Compod datasheet for more detail.
Features of the SmartTrak 101 Mass Flow Controller include:
- Measure and control flow of gas from 4 mln/min down to 0.08 mln/min
- Digital performance
- Includes Dial-A-Gas® multi-gas capability that enables use with 10 different gases
- 316 stainless steel construction suitable for any
- clean gas, even corrosives and toxics
- Small footprint makes installation easy
- Single-sided power input reduces installation cost and complexity
- Choose from multiple analog or digital signals
- Supports Modbus and Profibus DP
Specs
Contact Us Today To Enquire About Our Products And Services
Specification Detail of the SmartTrak 101 Mass Flow Controller:
Dial-A-Gas
+/- 1% of full scale in all 10 standard gases
Wetted Material
316 stainless steel, 416 stainless steel; Viton® “O”-rings and valve seat
standard; other elastomers are available (consult factory
Repeatability
+/- 0.2% of full scale
Accuracy
+/- 1% of full scale including linearity under calibration conditions
Temperature Coefficient
0.05% of Full Scale per °C, or better
Pressure Coefficient
0.15% of Full Scale per bar, or better
Output Signal – Analog
Linear 4 to 20 mA, 500 ohms maximum loop resistance and one of the following: Linear 0 to 5 VDC, 0 to 10 VDC, 1 to 5 VDC, 1000 ohms
minimum load resistance
Output Signal Digital
Standard RS232; Pilot Module Display optional
Gas & Ambient Temperature
0°C to 50°C
Leak Integrity
5 X 10-9 standard cc/sec of helium maximum
Gases
All clean gases including corrosives & toxics; specify when ordering. The following ten gases make up the Dial-A-Gas® feature of every MicroTrak™ instrument; up to nine alternate gases may be substituted.
Power Requirements
(Ripple noise not to exceed 100mV peak-to-peak)
For Mass Flow Meters:15 to 24 VDC +/- 10% (130 mA maximum)
For Mass Flow Controllers: 24 VDC +/- 10% (400 mA, regulated) for C101
Control Range For Controllers
2–100% of Full Scale flow; automatic shut-off at 1.9 %