Downloads
- Suitable for unknown/changing gas compositions
- No moving parts – no wearing
- Precise measurement already from 0.3 m/s
For technical and mixed gases – independent of gas composition – integrated pressure and temperature compensation – larger measuring range than many current Vortex flow meters.
- 04…20 mA, pulse and a Modbus RTU (RS 485) interface as standard
- Optional interfaces such as Modbus TCP (Ethernet), PoE, M-Bus
- Pressure range up to 40 bar
- Protection class IP 67
- Temperature range from -40°C to 100°C
- Integrated display for showing the measured values
- Available from DN15 to DN80
- Settings adjustable via the buttons on the display
- Main counter reading can be reset via the display
- For velocities from 0.3 m/s to 30 m/s
- High accuracy of 1% deviation of the measured value
Benefits at a glance
- Precise measurement starting at 0.3 m/s
- Suitable for unknown or changing gas compositions and mixed gases
- Rough industrial applications can be realised due to robust aluminium housing
- Measures operating volume flow and mass flow
- Measurement of the standard volume flow through integrated pressure and temperature measurement
- The innovative measuring principle guarantees precise flow measurement in different gases
- Suitable for rapidly changing temperature and pressure changes as well as large mass flows
- Larger measuring span than usual vortex flow sensors
- No moving parts, therefore low maintenance effort
- Negligible low pressure loss due to negligible low blockage of the diamete
Field of application:
- Technical gases
- Mixed gases
- Compressed air in PET bottles production
- CO2
- LPG
- Propane
- Crypton
Specs
Contact Us Today To Enquire About Our Products And Services
Product Specification
Below is the product specification of the VU 570 – Vortex ultrasonic flow sensor from CS Instruments. If you require further information, please contact our expert customer service advisors on 01722 442 307.
Measuring range:
See table
Measuring medium:
Air, non-aggressive gases and mixed gases (non-condensing)
Accuracy:
Volume flow (m3/h)
± 1,5 % m. v., optional
± 1 % m. v.
Mass flow (kg/h) resp. Standard volume flow (Nm3/h):
± 2 % m. v., optional ± 1,5 % m. v.
Meas. principle:
Vortex ultrasonic – Vortex frequency measurement
Process temp.:
-40°…+100°C
Process pressure:
Up to 40 bar (ü)
Protection class:
IP67
Material meas. Section and medium-touching parts:
Stainless steel 316, Plastic
Material display unit:
Aluminium – Die casting
Signal outputs:
As a standard:
RS 485 (Modbus-RTU), 1x 4…20 mA, puls
Optional: Ethernet Interface
Power supply:
18…36 VDC
Measuring span:
1:50
Repeatability:
± 0,3 % v. M.
Process connection:
Flange DIN EN1092-1 or Flange ANSI 150 lbs – 300 lbs R 1/2“ – R 2“ (BSP British Standard Piping)
1/2“ – 2“ NPT-thread