icenta-flow-meters-logo

VU 570 – Vortex ultrasonic sensor for flow measurement

partner-page-oval_orig

Downloads

fluidwell-f-series-cc-cx_548
  • Precise measurement from 0.3 m/s
  • Measures mass and operating volume flow
  • No moving parts, low maintenance required

VU 570 - Vortex ultrasonic sensor

Monitor and reduce your consumption and increase your sustainability with the VU 570. Monitor your consumption of different gas types and gas compositions with just one sensor.

  • Technical gases
  • Mixed gases
  • Compressed air in PET bottle production
  • CO2
  • LPG
  • Propane
  • Krypton
  • Precise measurement starting at 0.3 m/s
  • Suitable for unknown or changing gas compositions and mixed gases
  • Rough industrial applications can be realised due to robust aluminium housing
  • Measures operating volume flow and mass flow
  • Measurement of the standard volume flow through integrated pressure and temperature measurement
  • The innovative measuring principle guarantees precise flow measurement in different gases
  • Suitable for rapidly changing temperature and pressure changes as well as large mass flows
  • Larger measuring span than usual vortex flow sensors
  • No moving parts, therefore low maintenance effort
  • Negligible low pressure loss due to negligible low blockage of the diameter

Specs

Manufacturer: CS Instruments

Part Ref: VU 570

IWN: VU-570-VORTEX

Gas: Air, Clean Gas, Corrosives, Non-Aggressive Gases, Other Gas, Steam, Toxic

Approval: ATEX, UKCA/CE

Contact Us Today To Enquire About Our Products And Services


This versatile flow measurement solution offers robust design, high accuracy, and adaptability for reliable performance in diverse industrial applications.


Interfaces
04…20 mA, pulse, Modbus RTU (RS 485); optional: Modbus TCP (Ethernet), PoE, M-Bus

Pressure Range
Up to 40 bar

Protection Class
IP 67

Temperature Range
-40°C to 100°C

Display
Integrated display for measured values

Pipe Size
DN15 to DN80

Adjustability
Settings adjustable via display buttons

Main Counter
Resettable via the display

Velocity Range
0.3 m/s to 30 m/s

Accuracy
±1% of the measured value