The SITRANS Probe LU is a 2-wire loop powered ultrasonic transmitter for level, volume, and flow monitoring of liquids in open channels, storage vessels and simple process vessels. It is ideal for level monitoring in the water and wastewater industry and chemical storage vessels.
The range of SITRANS Probe LU is 6 or 12 m. Using Auto False-Echo Suppression for fixed obstruction avoidance, as well as an improved signal-to-noise ratio and improved accuracy of 0.15% of range or 6 mm, the Probe LU provides unmatched reliability.
SITRANS Probe LU includes Sonic Intelligence® signal processing from the field-proven Probe and incorporates new echo processing features and the latest micro-processor and communications technology. The Probe LU offers two communications options: HART or PROFIBUS PA (Profile version 3.0, Class B)
The transducer on the Probe LU is available as ETFE or PVDF to suit the chemical conditions of your application. As well, for applications with varying material and process temperatures, the Probe LU incorporates an internal temperature sensor to compensate for temperature changes.
Features of the SITRANS Probe LU include:
- Continuous level measurement up to 12 m range
- Easy installation and simple start-up
- Programming using infrared Intrinsically Safe handheld programmer, SIMATIC PDM or HART® Communicator.
- Communication using HART or PROFIBUS PA
- ETFE or PVDF transducers for chemical compatibility
- Patented Sonic Intelligence signal processing.
- Extremely high signal-to-noise ratio
- Auto False-Echo Suppression for fixed obstruction avoidance
- Level to volume or level to flow conversion.
Other Applications:
- Chemical storage vessels
- Filter beds
- Liquid storage vessels
Specs
Contact Us Today To Enquire About Our Products And Services
Product Specification
The SITRANS Probe LU is a 2-wire loop powered ultrasonic transmitter with intrinsically safe option for level, volume, and flow monitoring of liquids in open channels, storage vessels and simple process vessels.
Specification Detail of the SITRANS Probe LU:
Pipe Size
2″
Material Body
PBT
Measuring Range
6 or 12m
Accuracy
± 0.02 mA
Operating Temp Range
-40 to 85°C
Pressure Range
0.5 Bar g
Outputs & Comms
4 … 20mA HART/Profibus PA Profile 3, class B
Frequency
54KHz
Fluid Type
Liquid
Applicable Liquids
Water/wastewater
Power
24VDC with 550Ω max/ 12, 13, 15, or 20 mA
Approvals
CSA, FM, CE, C-TICK
Connection Type
Threaded – 2″NPT, R 2″ (BSPT), G 2″ (BSPP)Flange – 3″ (80mm) , FMS 200 mounting bracket