Parameter Comparison Table
Fluids | Flow range (m3/hr) | Nominal size (mm) | Linearity | Operating Temp (°C) | Max operating pressure (bar) | ATEX approval | |
Metri IC-LTM Turbine Flow Meter | Liquid | 0.28 – 550 | 6 – 150 (12 models) | < ± 0.25% of reading | 350 max | 400 (with threaded connection) | Yes |
Metri IC-GTM Turbine Flow Meter | Gas | 0.3 – 1960 | (19 model/size versions) | ± 2% | -30 to +120 | Limited only by end fittings | * |
2100 Turbine Flow Sensor | Liquid | 0.02 – 2.3 | 8, 10, 15(3 models) | ± 3% | -20 to 70 | 16 (@20 °C) | No |
EX Turbine Flowmeter | Liquid | 0.6 –4500 | 15 – 400(13 models) | ± 0.35% or ± 0.15% | 30 – +12030 – +300 (high temp model)-200 – –30 (low temp model) | 51 | Yes |